★ Cured Specifications: Cure speed will vary with temperature, relativehumidity, depth of material and presence of moisture.
Item | Part A | Part B | Mixed(20g) |
Open time @ 25℃ (min) | - | - | 2-3 |
Fixture time @ 25℃ (min) | - | - | 4-5 |
Viscosity (cps @ 23°C) | 8000-9000 | 9000-10000 | - |
Specific Gravity (g/cm³ @ 23°C) | 1.01 | 0.99 | 1.00 |
Color | Light Red | Light Green | White |
Mix Ratio | |||
By weight | 1 | 1 | - |
By volume | 1 | 1 | - |
Shelf life@ 25℃ (month) | 30 | 30 | - |
★ Cured Specifications: Cure speed will vary with temperature, relativehumidity, depth of material and presence of moisture.
Item | Part A | Part B | Mixed(20g) |
Open time @ 25℃ (min) | - | - | 2-3 |
Fixture time @ 25℃ (min) | - | - | 4-5 |
Viscosity (cps @ 23°C) | 8000-9000 | 9000-10000 | - |
Specific Gravity (g/cm³ @ 23°C) | 1.01 | 0.99 | 1.00 |
Color | Light Red | Light Green | White |
Mix Ratio | |||
By weight | 1 | 1 | - |
By volume | 1 | 1 | - |
Shelf life@ 25℃ (month) | 30 | 30 | - |
★ Test condition: Curing for 7 days @ 25±2_, 50±5% RH.
Standard | Item | Result |
/ | Operating Temperature Range(°C) | -60~120 |
ASTM D2095-96 | Tensile Strength (MPa) | 26 |
ASTM D1002-10 | Shear strength (MPa) | 23 |
ASTM D1876-08 | Peel Strength(N/cm) | 140 |
ASTM D950-03 | Impact Strength (KJ/m2) | 55 |
/ | Cured Shrinkage (cm/cm) | 0.01 |
★ Test condition: Curing for 7 days @ 25±2_, 50±5% RH.
Standard | Item | Result |
/ | Operating Temperature Range(°C) | -60~120 |
ASTM D2095-96 | Tensile Strength (MPa) | 26 |
ASTM D1002-10 | Shear strength (MPa) | 23 |
ASTM D1876-08 | Peel Strength(N/cm) | 140 |
ASTM D950-03 | Impact Strength (KJ/m2) | 55 |
/ | Cured Shrinkage (cm/cm) | 0.01 |
Application Method |
|
Storage And Shelf Life | Close the tube tightly after each use. Store product in the unopened container in a dry location. Optimal storage is between 46°F/8°C to 70°F /21°C,Shelf life is 30 months. |
Caution! |
|
Note | The information provided in this Technical Data Sheet (TDS) including the recommendations for use and application of the product are based on our knowledge and experience of the product as at the date of this TDS. The product can have a variety of different applications as well as differing application and working conditions in your environment that are beyond our control. Fenloc is, therefore, not liable for the suitability of our product for the production processes and conditions in respect of which you use them, as well as the intended applications and results. We strongly recommend that you carry out your own prior trials to confirm such suitability of our product. Any liability in respect of the information in the Technical Data Sheet or any other written or oral recommendation regarding the concerned product is excluded, except if otherwise explicitly agreed and except in relation to death or personal injury caused by our negligence and any liability under any applicable mandatory product liability law. For technical assistance, please call 400-188-7028. For complete safety and handling information, please refer to the appropriate Material Safety Data Sheets prior to using this product. |
Application Method |
|
Storage And Shelf Life | Close the tube tightly after each use. Store product in the unopened container in a dry location. Optimal storage is between 46°F/8°C to 70°F /21°C,Shelf life is 30 months. |
Caution! |
|
Note | The information provided in this Technical Data Sheet (TDS) including the recommendations for use and application of the product are based on our knowledge and experience of the product as at the date of this TDS. The product can have a variety of different applications as well as differing application and working conditions in your environment that are beyond our control. Fenloc is, therefore, not liable for the suitability of our product for the production processes and conditions in respect of which you use them, as well as the intended applications and results. We strongly recommend that you carry out your own prior trials to confirm such suitability of our product. Any liability in respect of the information in the Technical Data Sheet or any other written or oral recommendation regarding the concerned product is excluded, except if otherwise explicitly agreed and except in relation to death or personal injury caused by our negligence and any liability under any applicable mandatory product liability law. For technical assistance, please call 400-188-7028. For complete safety and handling information, please refer to the appropriate Material Safety Data Sheets prior to using this product. |